{"id":2929,"date":"2020-10-02T00:19:03","date_gmt":"2020-10-01T16:19:03","guid":{"rendered":"http:\/\/www.ukm.my\/icrim\/?post_type=product&#038;p=2929"},"modified":"2026-04-19T01:35:26","modified_gmt":"2026-04-18T17:35:26","slug":"gas-chromatography-mass-spectrometer-gc-ms","status":"publish","type":"product","link":"https:\/\/www.ukm.my\/icrim\/reservation\/gas-chromatography-mass-spectrometer-gc-ms\/","title":{"rendered":"Gas Chromatography &#8211; Mass Spectroscopy  (GC-MS)"},"content":{"rendered":"\t\t<div data-elementor-type=\"product-post\" data-elementor-id=\"2929\" class=\"elementor elementor-2929\" data-elementor-settings=\"{&quot;element_pack_global_tooltip_width&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_padding&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true}}\" data-elementor-post-type=\"product\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6572d9e ot-traditional elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6572d9e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2c6ced9 ot-flex-column-vertical\" data-id=\"2c6ced9\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-c3dcfb1 ot-traditional elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c3dcfb1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-5b79b36 ot-flex-column-vertical\" data-id=\"5b79b36\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-bf45a31 ot-traditional elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"bf45a31\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-66b30ab ot-flex-column-vertical\" data-id=\"66b30ab\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8638beb elementor-widget elementor-widget-heading\" data-id=\"8638beb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">All enquiries please contact:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Brand : Agilent<br \/>\nModel : 5977C GC\/MSD with 8890 GC &#038; 7697A Headspace Sampler<\/p>\n<p>Gas chromatography mass spectrometry (GC-MS) is an instrumental technique, comprising a gas chromatograph (GC) coupled to a mass spectrometer (MS), by which complex mixtures of chemicals may be separated, identified and quantified. This makes it ideal for the analysis of the hundreds of relatively low molecular weight compounds found in environmental materials. In order for a compound to be analysed by GC-MS, it must be sufficiently volatile and thermally stable. In addition, functionalised compounds may require chemical modification (derivation), prior to analysis, to eliminate undesirable adsorption effects that would otherwise affect the quality of the data obtained. Samples are usually analysed as organic solutions consequently materials of interest (e.g. soils, sediments, tissues etc.) need to be solvent extracted and the extract subjected to various &#8216;wet chemical&#8217; techniques before GC\/MS analysis is possible.<\/p>\n<p>The sample solution is injected into the GC inlet where it is vaporized and swept onto a chromatographic column by the carrier gas (usually helium). The sample flows through the column and the compounds comprising the mixture of interest are separated by virtue of their relative interaction with the coating of the column (stationary phase) and the carrier gas (mobile phase). The latter part of the column passes through a heated transfer line and ends at the entrance to ion source where compounds eluting from the column are converted to ions.<br \/>\nThe next component is a mass analyser (filter), which separates the positively charged ions according to various mass related properties depending upon the analyser used. Several types of analyzer exist: quadrupoles, ion traps, magnetic sector, time-of-flight, radio frequency, cyclotron resonance and focusing to name a few. The most common are quadrupoles and ion traps. After the ions are separated they enter a detector the output from which is amplified to boost the signal. The detector sends information to a computer that records all of the data produced, converts the electrical impulses into visual displays and hard copy displays. In addition, the computer also controls the operation of the mass spectrometer.<\/p>\n<p>For samples where the compounds of interest are trapped in complex or dirty matrices (such as blood, soil, or polymers), a Headspace Sampler is utilized to avoid injecting non-volatile material into the GC. This technique operates on the principle of partitioning equilibrium: a liquid or solid sample is sealed in a vial and heated to a constant temperature, causing volatile components to migrate into the gas phase (the &#8220;headspace&#8221;) above the sample. Once equilibrium is reached, a precise volume of this vapor is extracted and injected into the GC inlet. This ensures that only the volatile analytes enter the chromatographic column, protecting the system from contamination and simplifying sample preparation by eliminating the need for tedious solvent extractions.<\/p>\n","protected":false},"featured_media":9992,"template":"","meta":[],"product_brand":[],"product_cat":[59],"product_tag":[],"class_list":["post-2929","product","type-product","status-publish","has-post-thumbnail","product_cat-molecular-structure-characterization-lab","first","instock","featured","virtual","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Gas Chromatography - Mass Spectroscopy (GC-MS) - Makmal i-CRIM<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ukm.my\/icrim\/reservation\/gas-chromatography-mass-spectrometer-gc-ms\/\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Gas Chromatography - Mass Spectroscopy (GC-MS) - Makmal i-CRIM\" \/>\n<meta name=\"twitter:description\" content=\"Brand : Agilent Model : 5977C GC\/MSD with 8890 GC &amp; 7697A Headspace Sampler  Gas chromatography mass spectrometry (GC-MS) is an instrumental technique, comprising a gas chromatograph (GC) coupled to a mass spectrometer (MS), by which complex mixtures of chemicals may be separated, identified and quantified. This makes it ideal for the analysis of the hundreds of relatively low molecular weight compounds found in environmental materials. In order for a compound to be analysed by GC-MS, it must be sufficiently volatile and thermally stable. In addition, functionalised compounds may require chemical modification (derivation), prior to analysis, to eliminate undesirable adsorption effects that would otherwise affect the quality of the data obtained. Samples are usually analysed as organic solutions consequently materials of interest (e.g. soils, sediments, tissues etc.) need to be solvent extracted and the extract subjected to various &#039;wet chemical&#039; techniques before GC\/MS analysis is possible.  The sample solution is injected into the GC inlet where it is vaporized and swept onto a chromatographic column by the carrier gas (usually helium). The sample flows through the column and the compounds comprising the mixture of interest are separated by virtue of their relative interaction with the coating of the column (stationary phase) and the carrier gas (mobile phase). The latter part of the column passes through a heated transfer line and ends at the entrance to ion source where compounds eluting from the column are converted to ions. The next component is a mass analyser (filter), which separates the positively charged ions according to various mass related properties depending upon the analyser used. Several types of analyzer exist: quadrupoles, ion traps, magnetic sector, time-of-flight, radio frequency, cyclotron resonance and focusing to name a few. The most common are quadrupoles and ion traps. After the ions are separated they enter a detector the output from which is amplified to boost the signal. The detector sends information to a computer that records all of the data produced, converts the electrical impulses into visual displays and hard copy displays. In addition, the computer also controls the operation of the mass spectrometer.  For samples where the compounds of interest are trapped in complex or dirty matrices (such as blood, soil, or polymers), a Headspace Sampler is utilized to avoid injecting non-volatile material into the GC. This technique operates on the principle of partitioning equilibrium: a liquid or solid sample is sealed in a vial and heated to a constant temperature, causing volatile components to migrate into the gas phase (the &quot;headspace&quot;) above the sample. Once equilibrium is reached, a precise volume of this vapor is extracted and injected into the GC inlet. This ensures that only the volatile analytes enter the chromatographic column, protecting the system from contamination and simplifying sample preparation by eliminating the need for tedious solvent extractions.\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.ukm.my\/icrim\/wp-content\/uploads\/2020\/10\/GC-MS.png\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/reservation\\\/gas-chromatography-mass-spectrometer-gc-ms\\\/\",\"url\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/reservation\\\/gas-chromatography-mass-spectrometer-gc-ms\\\/\",\"name\":\"Gas Chromatography - Mass Spectroscopy (GC-MS) - Makmal i-CRIM\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/reservation\\\/gas-chromatography-mass-spectrometer-gc-ms\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/reservation\\\/gas-chromatography-mass-spectrometer-gc-ms\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/GC-MS.png\",\"datePublished\":\"2020-10-01T16:19:03+00:00\",\"dateModified\":\"2026-04-18T17:35:26+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/reservation\\\/gas-chromatography-mass-spectrometer-gc-ms\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/reservation\\\/gas-chromatography-mass-spectrometer-gc-ms\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/reservation\\\/gas-chromatography-mass-spectrometer-gc-ms\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/GC-MS.png\",\"contentUrl\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/GC-MS.png\",\"width\":1080,\"height\":1350},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/reservation\\\/gas-chromatography-mass-spectrometer-gc-ms\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Gas Chromatography &#8211; Mass Spectroscopy (GC-MS)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/#website\",\"url\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/\",\"name\":\"Makmal i-CRIM\",\"description\":\"Making an impact for your research\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/#organization\",\"name\":\"Makmal i-CRIM\",\"url\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/logo_icrim_single-01-01.jpg\",\"contentUrl\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/logo_icrim_single-01-01.jpg\",\"width\":696,\"height\":696,\"caption\":\"Makmal i-CRIM\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ukm.my\\\/icrim\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/makmalcrimukm\",\"https:\\\/\\\/www.instagram.com\\\/makmal_icrim\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Gas Chromatography - Mass Spectroscopy (GC-MS) - Makmal i-CRIM","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ukm.my\/icrim\/reservation\/gas-chromatography-mass-spectrometer-gc-ms\/","twitter_card":"summary_large_image","twitter_title":"Gas Chromatography - Mass Spectroscopy (GC-MS) - Makmal i-CRIM","twitter_description":"Brand : Agilent Model : 5977C GC\/MSD with 8890 GC & 7697A Headspace Sampler  Gas chromatography mass spectrometry (GC-MS) is an instrumental technique, comprising a gas chromatograph (GC) coupled to a mass spectrometer (MS), by which complex mixtures of chemicals may be separated, identified and quantified. This makes it ideal for the analysis of the hundreds of relatively low molecular weight compounds found in environmental materials. In order for a compound to be analysed by GC-MS, it must be sufficiently volatile and thermally stable. In addition, functionalised compounds may require chemical modification (derivation), prior to analysis, to eliminate undesirable adsorption effects that would otherwise affect the quality of the data obtained. Samples are usually analysed as organic solutions consequently materials of interest (e.g. soils, sediments, tissues etc.) need to be solvent extracted and the extract subjected to various 'wet chemical' techniques before GC\/MS analysis is possible.  The sample solution is injected into the GC inlet where it is vaporized and swept onto a chromatographic column by the carrier gas (usually helium). The sample flows through the column and the compounds comprising the mixture of interest are separated by virtue of their relative interaction with the coating of the column (stationary phase) and the carrier gas (mobile phase). The latter part of the column passes through a heated transfer line and ends at the entrance to ion source where compounds eluting from the column are converted to ions. The next component is a mass analyser (filter), which separates the positively charged ions according to various mass related properties depending upon the analyser used. Several types of analyzer exist: quadrupoles, ion traps, magnetic sector, time-of-flight, radio frequency, cyclotron resonance and focusing to name a few. The most common are quadrupoles and ion traps. After the ions are separated they enter a detector the output from which is amplified to boost the signal. The detector sends information to a computer that records all of the data produced, converts the electrical impulses into visual displays and hard copy displays. In addition, the computer also controls the operation of the mass spectrometer.  For samples where the compounds of interest are trapped in complex or dirty matrices (such as blood, soil, or polymers), a Headspace Sampler is utilized to avoid injecting non-volatile material into the GC. This technique operates on the principle of partitioning equilibrium: a liquid or solid sample is sealed in a vial and heated to a constant temperature, causing volatile components to migrate into the gas phase (the \"headspace\") above the sample. Once equilibrium is reached, a precise volume of this vapor is extracted and injected into the GC inlet. This ensures that only the volatile analytes enter the chromatographic column, protecting the system from contamination and simplifying sample preparation by eliminating the need for tedious solvent extractions.","twitter_image":"https:\/\/www.ukm.my\/icrim\/wp-content\/uploads\/2020\/10\/GC-MS.png","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ukm.my\/icrim\/reservation\/gas-chromatography-mass-spectrometer-gc-ms\/","url":"https:\/\/www.ukm.my\/icrim\/reservation\/gas-chromatography-mass-spectrometer-gc-ms\/","name":"Gas Chromatography - Mass Spectroscopy (GC-MS) - Makmal i-CRIM","isPartOf":{"@id":"https:\/\/www.ukm.my\/icrim\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ukm.my\/icrim\/reservation\/gas-chromatography-mass-spectrometer-gc-ms\/#primaryimage"},"image":{"@id":"https:\/\/www.ukm.my\/icrim\/reservation\/gas-chromatography-mass-spectrometer-gc-ms\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ukm.my\/icrim\/wp-content\/uploads\/2020\/10\/GC-MS.png","datePublished":"2020-10-01T16:19:03+00:00","dateModified":"2026-04-18T17:35:26+00:00","breadcrumb":{"@id":"https:\/\/www.ukm.my\/icrim\/reservation\/gas-chromatography-mass-spectrometer-gc-ms\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ukm.my\/icrim\/reservation\/gas-chromatography-mass-spectrometer-gc-ms\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ukm.my\/icrim\/reservation\/gas-chromatography-mass-spectrometer-gc-ms\/#primaryimage","url":"https:\/\/www.ukm.my\/icrim\/wp-content\/uploads\/2020\/10\/GC-MS.png","contentUrl":"https:\/\/www.ukm.my\/icrim\/wp-content\/uploads\/2020\/10\/GC-MS.png","width":1080,"height":1350},{"@type":"BreadcrumbList","@id":"https:\/\/www.ukm.my\/icrim\/reservation\/gas-chromatography-mass-spectrometer-gc-ms\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ukm.my\/icrim\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.ukm.my\/icrim\/shop\/"},{"@type":"ListItem","position":3,"name":"Gas Chromatography &#8211; Mass Spectroscopy (GC-MS)"}]},{"@type":"WebSite","@id":"https:\/\/www.ukm.my\/icrim\/#website","url":"https:\/\/www.ukm.my\/icrim\/","name":"Makmal i-CRIM","description":"Making an impact for your research","publisher":{"@id":"https:\/\/www.ukm.my\/icrim\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ukm.my\/icrim\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.ukm.my\/icrim\/#organization","name":"Makmal i-CRIM","url":"https:\/\/www.ukm.my\/icrim\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ukm.my\/icrim\/#\/schema\/logo\/image\/","url":"https:\/\/www.ukm.my\/icrim\/wp-content\/uploads\/2024\/04\/logo_icrim_single-01-01.jpg","contentUrl":"https:\/\/www.ukm.my\/icrim\/wp-content\/uploads\/2024\/04\/logo_icrim_single-01-01.jpg","width":696,"height":696,"caption":"Makmal i-CRIM"},"image":{"@id":"https:\/\/www.ukm.my\/icrim\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/makmalcrimukm","https:\/\/www.instagram.com\/makmal_icrim\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.ukm.my\/icrim\/wp-json\/wp\/v2\/product\/2929","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ukm.my\/icrim\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.ukm.my\/icrim\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":10,"href":"https:\/\/www.ukm.my\/icrim\/wp-json\/wp\/v2\/product\/2929\/revisions"}],"predecessor-version":[{"id":9996,"href":"https:\/\/www.ukm.my\/icrim\/wp-json\/wp\/v2\/product\/2929\/revisions\/9996"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ukm.my\/icrim\/wp-json\/wp\/v2\/media\/9992"}],"wp:attachment":[{"href":"https:\/\/www.ukm.my\/icrim\/wp-json\/wp\/v2\/media?parent=2929"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.ukm.my\/icrim\/wp-json\/wp\/v2\/product_brand?post=2929"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.ukm.my\/icrim\/wp-json\/wp\/v2\/product_cat?post=2929"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.ukm.my\/icrim\/wp-json\/wp\/v2\/product_tag?post=2929"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}