Take urgent action to combat climate change and its impacts
SDG 13 Indicator
13.2 – Low-carbon energy use
13.2.1 – Low-Carbon Energy Tracking
Universiti Kebangsaan Malaysia (UKM) has established robust systems to measure and maximize low-carbon energy use across campus, integrating energy-efficient appliances and equipment in buildings, streets, laboratories, and beyond. Through meticulous tracking of low-carbon energy consumption university-wide, we are committed to achieving impactful reductions in carbon emissions and leading by example in sustainable energy management.
UKM demonstrates strong institutional commitment toward achieving a low-carbon and energy-efficient campus through systematic tracking, monitoring and optimization of its energy use. As part of the university’s sustainability governance, UKM has established comprehensive mechanisms to measure the amount of low-carbon energy utilized across all facilities, including academic buildings, residential colleges, laboratories and public spaces. This commitment reflects UKM’s alignment with the UKM Sustainability Strategic Plan 2030 and the UKM Net Zero Campus 2040 vision.
UKM maintains energy-monitoring infrastructure through Digital Power Meters and the SEPADU spatial information platform, supporting building-level electricity reporting and consumption analysis. The University Integrated Spatial and Asset Information System (SEPADU), equipped with the Digital Power Meter (DPM), serves as a centralized platform for real-time monitoring of energy consumption across campus buildings. This system integrates spatial data and digital infrastructure information, enabling efficient tracking of electricity usage, maintenance management and visualization of energy performance. The SEPADU & DPM dashboard provides detailed analytics such as monthly energy usage (kWh) and cost breakdowns, empowering facilities managers to identify energy-saving opportunities and optimize low-carbon energy utilization.
In addition, the UKM Air Quality Monitoring Station, powered by the Derialah System, supports environmental sustainability through real-time monitoring of air quality and climate parameters. By capturing data on particulate matter, temperature, humidity and CO₂ levels, this system complements the energy monitoring dashboard in assessing the overall environmental impact of campus operations. Together, these digital platforms form UKM’s integrated approach to smart campus management, enabling precise measurement, reporting, and verification (MRV) of energy efficiency and sustainability indicators. Through these initiatives, UKM strengthens its commitment to low-carbon campus transformation, aligning with the Sustainability Strategic Plan 2030 and national goals for carbon neutrality by 2050.
UKM’s Digital Dashboard System for Real-Time Monitoring of Low-Carbon Energy and Environmental Performance:
1. University Integrated Spatial and Asset Information System (SEPADU): DIGITAL POWER METER (DPM)
Function: The SEPADU system was developed as an integrated asset information system based on spatial data, established a university infrastructure information system for efficient maintenance and data recording, and created a GIS UKM portal as a platform for facility management data sharing.
Link: www.gis.ukm.my

2. UKM Air Quality Monitoring Station: Real-time Environmental Data
Function: Derialah EA System is the real-time monitoring platform that reflects UKM’s commitment to environmental sustainability and public health. By tracking air quality, weather, and health indicators across campus, the system empowers data-driven actions towards a cleaner, healthier, and more sustainable UKM.
Link: derialah.com/board

In 2025, UKM committed to using energy-efficient appliance usage across its campus, a major milestone reflecting tangible progress in reducing electricity consumption and carbon emissions. Through large-scale implementation of LED lighting systems, inverter air conditioners, ENERGY STAR-certified computers and 5-star DC motor fans, the university ensures that energy demand is met through sustainable and efficient technologies. Complementing these upgrades, UKM’s 114-unit energy meter reader system enables real-time monitoring of building energy performance, while advanced infrastructure such as the District Cooling System (DCS) further enhances operational efficiency by optimizing chilled water production during off-peak hours.
Energy efficient appliances used in UKM
1. LEDs: campus outdoor lamp
UKM has replaced conventional lighting with high-efficiency LEDs in campus streets and building interiors, significantly reducing energy consumption while improving visibility and safety.
The installation of 2,117 energy-efficient LED outdoor lamps across its campus has successfully reduced total power consumption from 254,040 watts using conventional lighting to 127,020 watts with energy-efficient alternatives, achieving a significant 50% reduction in power demand. The transition to LED lighting enhances operational efficiency, reduces electricity costs and contributes to lowering carbon emissions.
- Total energy-efficient appliances: 2,117
- Total Rated Power with Conventional Appliances (Watts) : 2,117 units x 120 watts = 254,040 watts
- Total Rated Power with Energy-Efficient Appliances (Watts) : 2,117 units x 60 watts =127,020 watts
- Percentage of energy- savings (%): 50%


2. The UKM Stadium LED Floodlight
Upgrade Project is a significant energy efficiency initiative aimed at reducing power consumption and operational costs while improving sports infrastructure.
The installation of 16 energy-efficient LED floodlights at UKM Stadium has successfully reduced total power consumption from 32,000 watts using conventional floodlights to 19,200 watts with LED technology, achieving a significant 40% reduction in power demand. The transition to energy-efficient lighting enhances operational efficiency, reduces electricity costs and contributes to lowering carbon emissions while maintaining adequate illumination for sporting activities.
- Total energy-efficient appliances: 16
- Total Rated Power with Conventional Appliances (Watts) : 16 units x 2,000 watts = 32,000 watts
- Total Rated Power with Energy-Efficient Appliances (Watts) : 16 units x 1,200 watts = 19,200 watts
- Percentage of energy- savings (%): 40%

3. Use of high efficiency LEDs in the campus building
UKM utilised conventional fluorescent lighting consuming 36 watts per unit. Installation of 142,934 high-efficiency LED lights across campus buildings has successfully reduced total power consumption from 5,145,624 watts using conventional lighting to 2,572,812 watts with energy-efficient LEDs, achieving a significant 50% reduction in power demand. The transition to LED technology enhances energy efficiency, reduces operational costs and contributes to lowering carbon emissions while maintaining effective indoor illumination.
- Total energy-efficient appliances: 142,934
- Total Rated Power with Conventional Appliances (Watts) : 142,934 units x 36 watts = 5,145,624 watts
- Total Rated Power with Energy-Efficient Appliances (Watts) : 142,934 units x 18 watts = 2,572,812 watts
- Percentage of energy- savings (%): 50%


4. Use of energy-saving computer / Star-certified computers
UKM prioritizes ENERGY STAR-certified computers and encourages the use of notebooks over personal computers as notebooks are more energy-efficient, aligning with the university’s commitment to reduce overall power usage. The inventory of the computer and laptop can be excess by the link https://docs.google.com/spreadsheets/d/1_4yfPfGLLs5zwfU3m17_-zHmTYg3gXqt/edit?gid=811058871#gid=811058871
This initiative has successfully reduced total power consumption from 717,780 watts using conventional computers to 205,080 watts with energy-efficient alternatives, achieving a significant 71.43% reduction in power demand. The adoption of energy-efficient computing technology enhances operational efficiency, reduces electricity costs and contributes to lowering carbon emissions while supporting academic and administrative activities.
- Total energy-efficient appliances: 10,254
- Total Rated Power with Conventional Appliances (Watts) : 10,254 units x 70 watts =717,780 watts
- Total Rated Power with Energy-Efficient Appliances (Watts) : 10,254 units x 20 watts =205,080 watts
- Percentage of energy- savings (%): 71.43%

5. Star energy consumption fans at residential
In an effort to lower energy consumption, UKM has converted all fans, particularly in student residences, from AC to DC motor fans. These fans have a 5-star energy rating, consuming between 5-8 kWh, thereby contributing to substantial energy savings.
UKM committed to energy efficiency and sustainable campus living through the use of 3,349 five-star energy-rated fans in residential facilities. This initiative has successfully reduced total power consumption from 251,175 watts using conventional fans to 40,188 watts with energy-efficient alternatives, achieving an impressive 84% reduction in power demand. The adoption of energy-efficient fans enhances operational efficiency, reduces electricity costs and promotes environmentally responsible energy consumption while maintaining residents’ comfort.
- Total energy-efficient appliances: 3349
- Total Rated Power with Conventional Appliances (Watts) : 3,349 units x 75 watts =251,175 watts
- Total Rated Power with Energy-Efficient Appliances (Watts) : 3,349 units x 12 watts = 40,188 watts
- Percentage of energy- savings (%): 84%

6. Use of eco-friendly air conditioner / energy-efficient appliances are A/C with inverter technology
Use of eco-friendly air conditioner / energy-efficient appliances are A/C with inverter technology.
The campus has installed inverter technology air conditioners that optimize energy use by adjusting power based on cooling needs, ensuring efficient operation and reducing energy waste. The total eco-friendly air conditioner this year 2025 is 2,478.
UKM utilised conventional air-conditioning systems with higher energy consumption. By 2025, UKM had adopted energy-efficient inverter air conditioners that automatically adjust power consumption according to cooling requirements, with reported electricity cost savings of approximately 30%–50% compared with conventional systems.

7. Energy meter reader
There are a total of 114 unit energy meter readers installed in each of the UKM buildings to measure the energy efficiency of each building and control electrical leakage. The electric meter readings will start to record/monitor the electricity used at the beginning of each month until the end of the month. The energy usage report must be submitted to Suruhanjaya Tenaga (ST) every six months.
By 2025, UKM had installed 114 energy meter readers across university buildings to systematically monitor electricity consumption, identify potential energy inefficiencies and support effective energy management. Each monitoring device consumes approximately 3–5 watts, enabling continuous electricity tracking and reporting.


TOTAL
- Total energy-efficient appliances: 146,668
- Total conventional appliances: 47,507
- Total energy-efficient and conventional ones: 194,175
- Percentage of energy-efficient appliances to the total appliances (%): 75.53%
Other energy-efficient appliances used in UKM
8. Solar Light Installation
As part of its commitment to promoting renewable energy and sustainable campus infrastructure, Universiti Kebangsaan Malaysia (UKM) has expanded the installation of solar-powered LED lighting across its campus. This includes 10 new solar LED streetlights, each rated at 120 watts, under the UKM Gateway Project (Gerbang UKM) near the traffic lights along UKM’s main road, as well as 20 solar LED lights installed at Keris Mas Residential College. These initiatives aim to enhance campus safety, improve outdoor illumination, reduce dependence on conventional grid electricity and support UKM’s ongoing efforts towards energy efficiency, carbon emission reduction and low-carbon campus development.
By 2025, UKM had expanded the installation of solar-powered LED lighting across campus facilities, including six units at UKM Stadium, three units at Arena Sukan Azman Hashim and 20 units at Keris Mas Residential College. These installations support the use of renewable energy, reduce dependence on grid electricity and strengthen UKM’s commitment to low-carbon campus infrastructure.
A total of six solar lamps have been installed at Stadium UKM and three solar lamps at Arena Sukan Azman Hashim, demonstrating UKM’s ongoing commitment to expanding renewable energy use and promoting sustainable lighting solutions across its campus facilities.


9. Motion Sensor Lighting
UKM enhances energy efficiency through the installation of motion sensor lighting systems, ensuring lights operate only when spaces are occupied, thereby reducing unnecessary energy consumption and supporting a sustainable campus environment.
Visible details: Brand: OSRAM
Product Series: SubstiTUBE® Motion Sensor
Model: ST8S-1.2M 16W/865
Type: LED tube light with a microwave motion sensor
Length: 1.2 meters (120 cm)
Power: 16 watts
Light Color Code: 865
8 = Color Rendering Index (CRI) ≥ 80
65 = Approximately 6500K daylight white
Luminous Output: Around 1800 lumens (partially visible)
Sensor Type: Microwave sensor (can detect movement and automatically switch the light on/off)

Through systematic low-carbon energy tracking and the adoption of energy-efficient technologies, UKM continues to lead by example in campus sustainability and climate action. The university’s transition toward smart energy management, including IoT-based monitoring, renewable installations such as solar lighting and district cooling innovations, directly supports Malaysia’s Low Carbon Nation Aspiration 2040 and the global Sustainable Development Goals (SDG 7: Affordable and Clean Energy; SDG 13: Climate Action). UKM’s proactive efforts have not only reduced operational carbon footprints but also fostered a culture of energy responsibility among its students and staff. By integrating science-driven strategies and sustainable technologies, UKM strengthens its position as a national leader in low-carbon transformation, paving the way for a resilient, energy-efficient and carbon-neutral university of the future.
UKM’s metering infrastructure and SEPADU platform establish a practical foundation for accountable energy management. Building-level electricity records support consumption analysis, while renewable-energy installations and efficiency measures contribute to the university’s low-carbon transition. To demonstrate low-carbon energy tracking directly, the reporting should consolidate verified annual consumption by energy source within a consistent campus boundary. Linking these quantities to supporting records would enable UKM to report its low-carbon energy share transparently and assess progress towards its climate objectives under SDG 13: Climate Action.
10. Air Quality sensor in UKM Building
The air quality monitoring system at UKM is an IoT-based environmental monitoring network designed to track and analyze indoor environmental conditions within university facilities. This system integrates power meters, temperature sensors and humidity sensors to provide continuous, real-time data for environmental assessment and energy management.
The image shows an air quality display panel mounted on the wall, presenting live data on key environmental parameters within the monitored facility;
- Temperature (T): 24°C
- Relative Humidity (RH): 56%
- Particulate Matter (PM2.5): 6 µg/m³
- Carbon Dioxide (CO₂): 465 ppm
This initiative reflects UKM’s proactive approach toward ensuring a healthy, energy-efficient and sustainable indoor environment through smart monitoring technologies.



11. Energy Efficiency Brand photocopy
UKM has used Ricon photocopy in the administration office. Ricon is one of the brands that implement sustainability in their product (LINK). Ricon products also have the certificate under MyHIJAU (LINK).

MyHIJAU Mark is Malaysia’s official green recognition endorsed by the Government of Malaysia, bringing together certified green products and services that meet local and international environmental standards under one single mark.

12. District Cooling System (DCS)

A district cooling system (DCS) is a cooling system in which chilled water is produced by a plant and distributed to tenant buildings with insulating pipes. In UKM, there are two DCS in Loop 1 and Loop 2, which provides cooling systems for buildings in UKM, and has saved substantial electricity cost and space.
Almost all the main equipment in the plant uses a 415-Volt electricity supply with a total load of around 3.0 MVA. For energy-saving purposes, all motors are equipped with frequency inverters, and the control devices are placed in an air-conditioned room to maintain a controlled ambient operating temperature, ensuring optimal energy savings and the best possible lifespan. For fire safety, this room is also equipped with an environmentally friendly and user-friendly FM200 gas fire suppression system.
The DCS-TES plant system is fully controlled via computer. The control system, known as the “Thermal Energy Storage Control System” or TESCS, can operate either manually or automatically. When the system is set to “auto mode,” it will operate automatically according to the data programmed into it. It functions based on the load schedule or cooling load profile that has been pre-programmed in this control system.
The operating method of this cooling system plant can be carried out in several ways. When there is no cooling load requirement from the buildings, or when it is stopped at night, the chiller will be set to operate in order to produce chilled water for storage in the TES tank at a temperature of 4°C. The plant’s operating period during this time is referred to as “off-peak charging.” At night, the electricity tariff charged by Tenaga Nasional Berhad is lower, which helps reduce Universiti Kebangsaan Malaysia’s electricity consumption costs.
The system is also designed to allow a small amount of chilled water, supplied to the TES tank for storage, to be diverted to the reticulation piping for the building cooling systems that require it. However, the capacity that can be used directly in this way is limited.
The system also allows the chiller to send chilled water directly to the reticulation piping for the cooling system without passing through the TES tank. This can be done when the TES tank is not ready to receive chilled water for storage or when it is under maintenance. In this case, the supply temperature is 5.6°C.
A combination of supply from the chiller and the TES tank is common, especially during peak hours. The chiller will operate at a constant load, and any additional load required will be supplied by the TES tank. This operating mode benefits the chiller, as it allows it to function at maximum efficiency. When the cooling demand is low, the TES tank can supply the stored cooling energy using pumps without operating the chiller.
Through systematic low-carbon energy tracking and the adoption of energy-efficient technologies, UKM continues to lead by example in campus sustainability and climate action. The university’s transition toward smart energy management, including IoT-based monitoring, renewable installations such as solar lighting and district cooling innovations, directly supports Malaysia’s Low Carbon Nation Aspiration 2040 and the global Sustainable Development Goals (SDG 7: Affordable and Clean Energy; SDG 13: Climate Action). UKM’s proactive efforts have not only reduced operational carbon footprints but also fostered a culture of energy responsibility among its students and staff. By integrating science-driven strategies and sustainable technologies, UKM strengthens its position as a national leader in low-carbon transformation, paving the way for a resilient, energy-efficient and carbon-neutral university of the future.